Publication

Day and night home closed-loop insulin delivery in adults with type 1 diabetes: three-center randomized crossover study.

Journal : Diabetes care
Authors : Leelarathna L, Dellweg S, Mader JK, Allen JM, Benesch C, Doll W, Ellmerer M, Hartnell S, Heinemann L, Kojzar H, Michalewski L, Nodale M, Thabit H, Wilinska ME, Pieber TR, Arnolds S, Evans ML, Hovorka R,
10.2337/dc13-2911 : DOI
24963110 : PMID

Objective

To evaluate the feasibility of day and night closed-loop insulin delivery in adults with type 1 diabetes under free-living conditions.

Research Design And Methods

Seventeen adults with type 1 diabetes on insulin pump therapy (means ± SD age 34 ± 9 years, HbA1c 7.6 ± 0.8%, and duration of diabetes 19 ± 9 years) participated in an open-label multinational three-center crossover study. In a random order, participants underwent two 8-day periods (first day at the clinical research facility followed by 7 days at home) of sensor-augmented insulin pump therapy (SAP) or automated closed-loop insulin delivery. The primary end point was the time when sensor glucose was in target range between 3.9 and 10.0 mmol/L during the 7-day home phase.

Results

During the home phase, the percentage of time when glucose was in target range was significantly higher during closed-loop compared with SAP (median 75% [interquartile range 61-79] vs. 62% [53-70], P = 0.005). Mean glucose (8.1 vs. 8.8 mmol/L, P = 0.027) and time spent above target (P = 0.013) were lower during closed loop, while time spent below target was comparable (P = 0.339). Increased time in target was observed during both daytime (P = 0.017) and nighttime (P = 0.013).

Conclusions

Compared with SAP, 1 week of closed-loop insulin delivery at home reduces mean glucose and increases time in target without increasing the risk of hypoglycemia in adults with relatively well-controlled type 1 diabetes.