Background
Time in range is a key glycemic metric, and comparisons of management technologies for this outcome are critical to guide device selection.
Purpose
We conducted a systematic review and network meta-analysis to compare and rank technologies for time in glycemic ranges.
Data Sources
We searched Evidenced-Based Medicine Reviews, CINAHL, Embase, MEDLINE, MEDLINE In-Process & Other Non-Indexed Citations, PROSPERO, PsycInfo, PubMed, and Web of Science until 24 April 2019.
Study Selection
We included randomized controlled trials ≥2 weeks’ duration comparing technologies for management of type 1 diabetes in adults (≥18 years of age), excluding pregnant women.
Data Extraction
Data were extracted using a predefined template. Outcomes were percent time with sensor glucose levels 3.9-10.0 mmol/L (70-180 mg/dL), >10.0 mmol/L (180 mg/dL), and <3.9 mmol/L (70 mg/dL).
Data Synthesis
We identified 16,772 publications, of which 14 eligible studies compared eight technologies comprising 1,043 participants. Closed-loop systems led to greater percent time in range than any other management strategy, and mean percent time in range was 17.85 (95% predictive interval 7.56-28.14) longer than with usual care of multiple daily injections with capillary glucose testing. Closed-loop systems ranked best for percent time in range or above range with use of Surface Under the Cumulative RAnking curve (SUCRA) (98.5% and 93.5%, respectively). Closed-loop systems also ranked highly for time below range (SUCRA 62.2%).
Limitations
Overall risk of bias ratings were moderate for all outcomes. Certainty of evidence was very low.
Conclusions
In the first integrated comparison of multiple management strategies considering time in range, we found that the efficacy of closed-loop systems appeared better than all other approaches.